Fujitsu Ductless Heat Pumps     logo-fujitsu.gif

Wall Mounted I.A.Q. 9 - 12,000 BTU

Indoor Unit
Systems: 9CQ, 9RQ, 9RLQ, 12CQ,
12RQ, 12RLQ

Outdoor Unit
Systems: 9CQ, 9RQ, 9RLQ, 12CQ,
12RQ, 12RLQ

This category of equipment is ideal for smaller spaces where spot cooling or heating is required. Several models in this category are ENERGY STAR qualified, meaning they save you money on your utility bill. Residential applications including sunrooms and additions are made easier with these air conditioners and heat pumps. Do you have a warm spot in your home? Our mini-splits can provide extra cooling capacity for those hard to cool areas. Commercially, their small size makes them ideal for small offices, providing individual temperature control.

SYSTEM 9CQ 9RQ 9RLQ 12CQ 12RQ 12RLQ
CAPACITIES:  
Cooling BTU/h 9,700 9,700 9,000 12,300 12,300 12,000
Outdoor Design Temp
F° DB/WB
95/75 95/75 95/75 95/75 95/75 95/75
Outdoor Design Temp
F° DB/WB
- 9,600 12,000 - 12,300 16,000
Outdoor Design Temp
F° DB/WB
- 47/43 47/43 - 47/43 47/43
SEER 14.3 14.3 21.0 13.5 13.7 21.0
EER Clg/Htg 11.8 11.8/13.9 13.5/14.5 11.6 11.5/12.9 12.5/12.8
HSPF - 8.2 11 - 8.2 10.55
Power Supply (V) 115 115 208-230 115 115 208-230
INDOOR UNIT:  
Noise Level db (A) Cooling
                           Hi
                           Med
                           Lo

40
36
31
-
42
37
31

45
40
35
-
43
37
31
Noise Level db (A) Heating
                           Hi
                           Med
                           Lo
-
40
36
31

42
37
30
-
45
40
35

42
37
30
Weight (lbs.) 21 21 21 21 21 21
OUTDOOR UNIT:  
Max Fuse Size (A) 15 15 20 20 20 20
Min. Ampacity (A) 12 12 10 15 15 12
Running Current Clg (A)Rated/Max 7.6 7.6 3.2/6.0 9.8 9.9 4.5/7.0
Running Current Htg (A)Rated/Max - 6.5 3.9/8.5 - 9.2 5.7/10.0
Weight (lbs.) 68 71 77 77 79 82
REFRIGERANT PIPING:  
Max Ht. Difference (ft.) 26 26 49 26 26 49
Max Total or Combined Length (ft.) 49 49 66 49 49 66
Discharge Vapor Line (O.D.) inches 1/4 1/4 1/4 1/4 1/4 1/4
Suction (O.D.) inches 3/8 3/8 3/8 3/8 3/8 3/8

Wall Mounted I.A.Q. 15 - 18,000 BTU

Indoor Unit
Systems: 9CQ, 9RQ, 9RLQ, 12CQ,
12RQ, 12RLQ

Outdoor Unit
Systems: 9CQ, 9RQ, 9RLQ, 12CQ, 
12RQ, 12RLQ

This category of equipment is ideal for medium to large spaces where it can conveniently condition a large open area within minutes. Residential applications including sunrooms and additions are made easier with these air conditioners and heat pumps. Do you have a warm spot in your home? Our mini-splits can provide extra cooling capacity for those hard to cool areas. Commercially, their small size makes them ideal for offices, providing individual temperature control.

SYSTEM 24RLXQ 30RLXQ
CAPACITIES:  
Cooling BTU/h 24,200 30,600
Outdoor Design Temp
F° DB/WB
95/75 95/75
Outdoor Design Temp
F° DB/WB
27,600 32,000
Outdoor Design Temp
F° DB/WB
47/43 47/43
SEER 17 15
EER Clg/Htg 11.1/11.6 7.9/10.7
HSPF 10 9.5
Power Supply (V) 208-230 208-230
INDOOR UNIT:  
Noise Level db (A) Cooling
                           Hi
                           Med
                           Lo

49
44
39

49
44
39
Noise Level db (A) Heating
                           Hi
                           Med
                           Lo

49
44
39

49
44
39
Weight (lbs.) 31 31
OUTDOOR UNIT:  
Max Fuse Size (A) 30 30
Min. Ampacity (A) 22 22
Running Current Clg (A)Rated/Max 9.6/15 17.0/18.5
Running Current Htg (A)Rated/Max 10.5/15.5 13.2/18.5
Weight (lbs.) 137 137
REFRIGERANT PIPING:  
Max Ht. Difference (ft.) 98 98
Max Total or Combined Length (ft.) 164 164
Discharge Vapor Line (O.D.) inches 3/8 3/8
Suction (O.D.) inches 5/8 5/8

Inverter Technology (9RLQ, 12RLQ only)
Through new, advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature more quickly than conventional air conditioners.

Inverter Control (9RLQ, 12RLQ only)
The Inverter component allows the outdoor unit to vary its speed and output to match the required capacity of the indoor unit. Thus, the Inverter model can achieve 30% more operating efficiency than conventional models and therefore, is much less expensive to run.

Energy Efficient
All I.A.Q. systems are highly energy efficient, saving you money on your utility bill. Systems 9CQ, 9RQ, 9RLQ and 12RLQ meet the criteria for ENERGY STAR® qualification in 2008.

Indoor Air Quality (I.A.Q.)
Fujitsu’s I.A.Q. systems provide residential and commercial property owners an innovative solution for clean, temperature-controlled indoor air. Halcyon I.A.Q. systems help to create a comfortable indoor environment by removing airborne irritants, odors and allergens such as cigarette smoke, dust, pollen, mold spores and pet dander. 

The plasma filter’s electric pole generates ions and while negatively-charged particles are attracted to the ground section and are collected by a disinfecting and deodorizing filter. The filters are especially useful at reducing pet and cigarette odors. Halcyon I.A.Q. systems feature super-charged plasma ionization and electrostatic filtration systems that ionize the airborne contaminants, neutralize them and provide clean air.

Quiet Operation
Wall mounted systems include an extra quiet fan speed ("Quiet Mode") to make sure that you are not disturbed.

Wireless Remote Controller
Wall mounted systems include an extra quiet fan speed ("Quiet Mode") to make sure that you are not disturbed.

Washable Panel Filter
The removable and washable panel filter is an effective air cleanser, removing mold & dust from the environment. Cleaning of the indoor unit itself is simple due to the design and shape of the casing. 

Smart System: Auto Mode
When the system is initially turned on, the fan speed is HIGH to reach the set temperature as quickly as possible. The fan speed will automatically adjust downward as the room begins to reach the set temperature.

Humidity Control
This system features Dry Mode, which helps to control humidity levels, even when cooling may not be needed.

Other Standard Features Include:

Sleep Timer					Auto Changeover
24-Hour Timer					Cold Prevention
Auto Restart/Reset				Low Ambient
Auto Louver:  Up/Down			Coil Dry Mode (9RLQ, 12RLQ only)